Canada Oil and Gas Geophysical Operations Regulations (SOR/96-117)
Full Document:
- HTMLFull Document: Canada Oil and Gas Geophysical Operations Regulations (Accessibility Buttons available) |
- XMLFull Document: Canada Oil and Gas Geophysical Operations Regulations [99 KB] |
- PDFFull Document: Canada Oil and Gas Geophysical Operations Regulations [272 KB]
Regulations are current to 2025-10-28
SCHEDULE III(Paragraph 20(3)(c))
Minimum Distance Between Charge and Commercial Electromagnetic Transmitters
| Column I | Column II | |
|---|---|---|
| Item | Transmitter Power Delivered to Antenna (w) | Distance (m) |
| 1 | not more than 500 | 140 |
| 2 | more than 500 but not more than 1,000 | 200 |
| 3 | more than 1,000 but not more than 2,500 | 305 |
| 4 | more than 2,500 but not more than 5,000 | 460 |
| 5 | more than 5,000 but not more than 10,000 | 670 |
| 6 | more than 10,000 but not more than 25,000 | 1,070 |
| 7 | more than 25,000 but not more than 50,000 | 1,520 |
| 8 | more than 50,000 but not more than 100,000 | 2,160 |
| 9 | more than 100,000 | 4,480 |