SCHEDULE I(Paragraph 17(1)(c))
Minimum Distance Between a Charge and Any Oil or Gas Well or the Centre Line of Any Oil or Gas Pipeline
| Column I | Column II | |
|---|---|---|
| Item | Net Weight of Explosive (kg) | Distance (m) |
| 1 | not more than 2 | 32 |
| 2 | more than 2 but not more than 4 | 45 |
| 3 | more than 4 but not more than 6 | 55 |
| 4 | more than 6 but not more than 8 | 64 |
| 5 | more than 8 but not more than 10 | 70 |
| 6 | more than 10 but not more than 20 | 100 |
| 7 | more than 20 but not more than 40 | 142 |
| 8 | more than 40 but not more than 100 | 225 |
| 9 | more than 100 | 500 |