Expansion Gates and Expandable Enclosures Regulations (SOR/2016-179)
Full Document:
- HTMLFull Document: Expansion Gates and Expandable Enclosures Regulations (Accessibility Buttons available) |
- XMLFull Document: Expansion Gates and Expandable Enclosures Regulations [28 KB] |
- PDFFull Document: Expansion Gates and Expandable Enclosures Regulations [239 KB]
Regulations are current to 2024-11-26 and last amended on 2022-12-19. Previous Versions
SCHEDULE 1(Section 1)Tests for Indelibility and Durability
1 The following method is to be used for testing the indelibility of markings in relation to labelling:
(a) spray the marked or printed surface with a glass cleaner;
(b) let the marked or printed surface soak for 20 seconds;
(c) using a back and forth motion, lightly rub the marked or printed surface 10 times within 10 seconds with an all-purpose cloth; and
(d) note and record whether the markings or printing have faded or erased.
2 The following method is to be used for testing whether a label is permanently affixed:
(a) spray the label with a glass cleaner;
(b) let the label soak for 20 seconds;
(c) apply light pressure and, using a motion towards the centre of the label, scrub the label at each corner 10 times within 10 seconds with an all-purpose nylon scrub pad;
(d) starting at one end of the label, attempt with bare fingers to lift and peel; and
(e) note and record whether the label can be removed in one piece.