Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Potato Processing Plant Liquid Effluent Regulations (C.R.C., c. 829)

Regulations are current to 2024-10-30

SCHEDULE II(Section 9)

Analytical Test Methods For Determining Presence and Concentrations of Deleterious Substances in Effluents

Column IColumn II
ItemDeleterious SubstanceTest MethodsModifications
1Biochemical Oxygen Demanding Matter (BOD)APHAFootnote for Analytical Test Methods For Determining Presence and Concentrations of Deleterious Substances in Effluents* Section 507For determining dissolved oxygen the following tests are recommended:
Section 422 B APHAFootnote for Analytical Test Methods For Determining Presence and Concentrations of Deleterious Substances in Effluents* or
Section 422 F APHAFootnote for Analytical Test Methods For Determining Presence and Concentrations of Deleterious Substances in Effluents*, the probe must be standardized against Winkler-Azide method (Section 422 B, APHAFootnote for Analytical Test Methods For Determining Presence and Concentrations of Deleterious Substances in Effluents*)
2Total Suspended MatterAPHAFootnote for Analytical Test Methods For Determining Presence and Concentrations of Deleterious Substances in Effluents* Section 208 D
  • Return to footnote *Refers to the publication Standard Methods for the Examination of Water and Waste Water, 14th Edition (1975), published jointly by the American Public Health Association, American Water Works Association and the Water Pollution Control Federation.

 

Date modified: