Energy Efficiency Regulations, 2016

Version of section 380 from 2023-06-21 to 2024-11-26:


Marginal note:Energy efficiency standards — household

  •  (1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to household oil-fired water heaters described in column 1 that are manufactured during the period set out in column 4.

  • Marginal note:Testing standard — household

    (2) An oil-fired water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a oil-fired water heater as defined in section 378.

  • Marginal note:Energy efficiency standards — commercial

    (3) The energy efficiency standards set out in column 2 of Table 2 to this section apply to commercial oil-fired water heaters described in column 1 that are manufactured on or after January 1, 2020.

  • Marginal note:Testing standard — commercial

    (4) A commercial oil-fired water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 2 that are applicable to an oil-fired water heater as defined in section 378.

    TABLE 1

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture
    1Household oil-fired water heatersCSA B211-00Energy factor of ≥ 0.59 – 0.0005 VrOn or after February 3, 1995 and before December 31, 2016
    2Household oil-fired water heatersCSA B211-00Energy factor of ≥ 0.68 – 0.0005 VrOn or after December 31, 2016 and before January 1, 2018
    3Household oil-fired water heaters that have a first-hour rating of < 68 L (18 US gallons)

    CSA B211-00 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.68 – 0.0005 Vr; or

    • (b) uniform energy factor of ≥ 0.2509 – 0.00032 Vs.

    On or after January 1, 2018
    4Household oil-fired water heaters that have a first-hour rating of ≥ 68 L (18 US gallons) but < 193 L (51 US gallons)

    CSA B211-00 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.68 – 0.0005 Vr; or

    • (b) uniform energy factor of ≥ 0.5330 – 0.00042 Vs.

    On or after January 1, 2018
    5Household oil-fired water heaters that have a first-hour rating of ≥ 193 L (51 US gallons) but < 284 L (75 US gallons)

    CSA B211-00 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.68 – 0.0005 Vr; or

    • (b) uniform energy factor of ≥ 0.6078 – 0.00042 Vs.

    On or after January 1, 2018
    6Household oil-fired water heaters that have a first-hour rating of ≥ 284 L (75 US gallons)

    CSA B211-00 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.68 – 0.0005 Vr; or

    • (b) uniform energy factor of ≥ 0.6815 – 0.00037 Vs.

    On or after January 1, 2018

    TABLE 2

    Column 1Column 2Column 3
    ItemEnergy-using ProductTesting StandardEnergy Efficiency Standard
    1Commercial oil-fired water heaters that have an input rate of > 30.5 kW (105,000 Btu/h) but ≤ 40.99 kW (140,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power, limit water temperatures to < 82°C (180°F) and are manufactured on or after January 1, 2020CSA P.3-15Uniform energy factor ≥ 0.6740 - 0.00035 Vs
    2Commercial oil-fired water heaters with a Vr of > 530 L (140 US gallons) that are manufactured on or after January 1, 202010 C.F.R. Appendix AThermal efficiency ≥ 80%
    3Commercial oil-fired water heaters, other than those described in items 1 and 2, that are manufactured on or after January 1, 202010 C.F.R. Appendix A

    Thermal efficiency ≥ 80%

    Standby loss ≤ 1.25 Q + 16.57√Vs

  • SOR/2018-201, s. 41
  • SOR/2019-164, s. 38
  • SOR/2022-265, s. 27
  • SOR/2022-265, s. 47