Marginal note:Information

 For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an oil-fired boiler described in column 1.

TABLE

Column 1Column 2Column 3
ItemEnergy-using ProductTesting StandardInformation
1Household oil-fired boilers manufactured on or after December 31, 1998 and before September 1, 2010CSA B212
  • (a) input rate, in kW (Btu/h); and

  • (b) seasonal energy utilization efficiency.

2Household oil-fired boilers manufactured on or after September 1, 2010 and before January 15, 2021ASHRAE 103 for information set out in paragraphs (a) to (f)
  • (a) type of central heating system for which product is intended;

  • (b) maximum heat input and output nominal capacities, in kW (Btu/h);

  • (c) power burner’s PE;

  • (d) water pump’s BE;

  • (e) average annual electrical energy consumption (EAE), in kWh;

  • (f) annual fuel utilization efficiency; and

  • (g) if product is manufactured on or after September 1, 2012,

    • (i) information that indicates whether product has tankless domestic water heating coils, and

    • (ii) type of automatic water temperature adjustment device product has, if any.

3Household oil-fired boilers manufactured on or after January 15, 2021CSA P.2 for information set out in paragraphs (a) to (e)
  • (a) type of central heating system for which product is intended;

  • (b) maximum heat input and output nominal capacities, in kW (Btu/h);

  • (c) annual fuel utilization efficiency;

  • (d) standby power, in W;

  • (e) off-mode power, in W;

  • (f) information that indicates whether product has tankless domestic water heating coils; and

  • (g) type of automatic water temperature adjustment device product has, if any.

4Commercial oil-fired boilers manufactured on or after January 1, 202510 C.F.R. Appendix A
  • (a) type of central heating system for which product is intended;

  • (b) maximum heat input nominal capacity, in kW (Btu/h); and

  • (c) thermal efficiency or, if product has an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and is intended for hot water systems, combustion efficiency.

  • SOR/2019-164, s. 23
  • SOR/2022-265, s. 47