Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 134 from 2022-12-21 to 2024-11-26:


Marginal note:Energy efficiency standards — single-phase

  •  (1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase split-system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Energy efficiency standards — three-phase

    (1.1) The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase split-system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A split-system central air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split-system central air conditioner as defined in section 132.

    TABLE 1

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture
    1Split system central air conditioners, other than those that are small-duct and high-velocity

    CSA C656-14 for seasonal energy efficiency ratio

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 13.0

    Off mode power consumption ≤ 30 W

    On or after February 3, 1995 and before January 1, 2023
    2Split system central air conditioners that are small-duct and high-velocity

    CSA C656-14 for seasonal energy efficiency ratio

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 12.0

    Off mode power consumption ≤ 30 W

    On or after February 3, 1995 and before January 1, 2023
    3Split system central air conditioners, other than those that are space-constrained or small-duct and high-velocity10 C.F.R. Appendix M1

    Seasonal energy efficiency ratio 2 ≥ 13.4

    Off mode power consumption ≤ 30 W

    On or after January 1, 2023
    4Split system central air conditioners that are small-duct and high-velocity10 C.F.R. Appendix M1

    Seasonal energy efficiency ratio 2 ≥ 12.0

    Off mode power consumption ≤ 30 W

    On or after January 1, 2023
    5Split system central air conditioners that are space-constrained10 C.F.R. Appendix M1

    Seasonal energy efficiency ratio 2 ≥ 11.7

    Off mode power consumption ≤ 30 W

    On or after January 1, 2023

    TABLE 2

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture
    1Split system central air conditioners, other than those that are small-duct and high-velocityCSA C656-14Seasonal energy efficiency ratio ≥ 13.0On or after February 3, 1995
    2Split system central air conditioners that are small-duct and high-velocityCSA C656-14Seasonal energy efficiency ratio ≥ 12.0On or after February 3, 1995
  • SOR/2019-163, s. 25
  • SOR/2022-265, s. 10

Date modified: