Multi-Sector Air Pollutants Regulations

Version of section 28 from 2016-06-17 to 2025-11-20:


Marginal note:Concentrations of NOx and O2

  •  (1) For each test run, the measurements of the concentration of NOx, expressed in ppmvd, and the concentration of O2, expressed as a percentage determined by volume on a dry basis, in the boiler’s or heater’s flue gas must be made simultaneously and in accordance with either

    • (a) the following EPA methods:

      • (i) for the location of the sampling port and its traverse points, EPA Method 1 or EPA Method 1A, as applicable,

      • (ii) for the concentration of NOx, EPA Method 7E, and

      • (iii) for the concentration of O2, EPA Method 3A; or

    • (b) ASTM D6522-11 and, for the location of the sampling port and its traverse points, EPA Method 1 or EPA Method 1A, as applicable.

  • Marginal note:Exception — EC Method A

    (2) Despite subsection (1), the location of the sampling port and its traverse points may be determined for the purpose of that subsection in accordance with EC Method A.