Multi-Sector Air Pollutants Regulations
Marginal note:Concentrations of NOx and O2
28 (1) For each test run, the measurements of the concentration of NOx, expressed in ppmvd, and the concentration of O2, expressed as a percentage determined by volume on a dry basis, in the boiler’s or heater’s flue gas must be made simultaneously and in accordance with either
(a) the following EPA methods:
(i) for the location of the sampling port and its traverse points, EPA Method 1 or EPA Method 1A, as applicable,
(ii) for the concentration of NOx, EPA Method 7E, and
(iii) for the concentration of O2, EPA Method 3A; or
(b) ASTM D6522-11 and, for the location of the sampling port and its traverse points, EPA Method 1 or EPA Method 1A, as applicable.
Marginal note:Exception — EC Method A
(2) Despite subsection (1), the location of the sampling port and its traverse points may be determined for the purpose of that subsection in accordance with EC Method A.