Multi-Sector Air Pollutants Regulations
Marginal note:Identification — exception to paragraph 25(b)
26 (1) The NOx emission intensity of a boiler or heater that is to be determined under paragraph 25(b) must be determined for a given hour in accordance with subsection (2), if the boiler or heater
(a) is not equipped with a CEMS; and
(b) has been identified under subsection (5) with another boiler or heater whose NOx emission intensity is determined for that given hour by means of a CEMS test as a rolling hourly average.
Marginal note:Greater of stack test and CEMS test
(2) The NOx emission intensity of a boiler or heater referred to in paragraph (1)(a) for each hour is the greater of
(a) the result of a stack test that is applicable to that hour, and
(b) the rolling hourly average for that hour determined by means of a CEMS test conducted on the other boiler or heater referred to in paragraph (1)(b).
Marginal note:Identification
(3) A boiler or heater referred to in paragraph (1)(a) may be identified with another boiler or heater referred to in paragraph (1)(b) if the following conditions are met:
(a) they have the same manufacturer;
(b) they have the same rated capacity;
(c) they are designed to have the same NOx emission intensity;
(d) they have the same equipment to preheat air, if any;
(e) they combust fuel from a common source;
(f) they are juxtaposed; and
(g) they are
(i) both class 80,
(ii) both class 70,
(iii) both transitional or modern, or one is transitional and the other is modern, or
(iv) both redesigned within the meaning of paragraph 10(2)(b).
Marginal note:When identification made
(4) The identification is made as of
(a) for class 80 boilers or heaters, the earlier of
(i) the recommissioning date of the boiler or heater referred to in paragraph (1)(a), if it underwent a major modification, and
(ii) January 1, 2026;
(b) for class 70 boilers or heaters, the earlier of
(i) the recommissioning date of the boiler or heater referred to in paragraph (1)(a), if it underwent a major modification, and
(ii) January 1, 2036;
(c) for transitional or modern boilers or heaters, the commissioning date of the boiler or heater referred to in paragraph (1)(a); and
(d) for redesigned boilers or heaters referred to in section 10, the recommissioning date of the boiler or heater referred to in paragraph (1)(a).
Marginal note:Identification by recording
(5) The identification is made on the recording of the following information:
(a) the name of the manufacturer — along with the serial number, make and model — of the boiler or heater referred to in paragraph (1)(a);
(b) the name of the manufacturer — along with the serial number, make and model — of the other boiler or heater referred to in paragraph (1)(b);
(c) documentation that establishes that those boilers or heaters meet the conditions set out in paragraphs (3)(b) to (g);
(d) an indication that the boiler or heater referred to in paragraph (a) is identified with the boiler or heater referred to in paragraph (b); and
(e) the date of the recording.
Marginal note:At most four identifications
(6) At most four boilers or heaters may be identified under subsection (5) with a given other boiler or heater referred to in paragraph (1)(b).