Safety of Human Cells, Tissues and Organs for Transplantation Regulations (SOR/2007-118)

Regulations are current to 2013-05-26 and last amended on 2008-06-08. Previous Versions

Retrieval

Marginal note:Retrieval interval — tissues

 An establishment that retrieves tissue from a deceased donor must carry out the retrieval within the scientifically based maximum interval between the cardiac asystole of the donor and the retrieval of the tissue.

Testing

Marginal note:Licensed diagnostic devices
  •  (1) Subject to subsection (2), in vitro diagnostic devices that are used by an establishment in the testing of donor blood for transmissible disease agents or markers under these Regulations must be licensed either

    • (a) in Canada, if the testing is performed in Canada; or

    • (b) in Canada or the United States, if the testing is performed outside Canada.

  • Marginal note:Exception — lymphohematopoietic cells

    (2) In the case of lymphohematopoietic cells that are imported into Canada for transplantation into a specific recipient, the in vitro diagnostic devices may be licensed in Canada or any other jurisdiction.

Marginal note:In vitro diagnostic devices — cells and tissues
  •  (1) In the case of cells and tissues, in vitro diagnostic devices that are used by an establishment in the testing of donor blood for transmissible disease agents or markers under these Regulations must be licensed for screening donors.

  • Marginal note:Exception — syphilis

    (2) Despite subsection (1), in vitro diagnostic devices that are used in the testing of donor blood for syphilis may be licensed either for diagnosis or screening donors.

Marginal note:Bacteriological testing — tissues

 An establishment that retrieves tissue, except ocular tissue, must perform bacteriological testing in accordance with section 14.3 of the tissue standard, except for section 14.3.2.8.

Packaging and Labelling

Packaging

Marginal note:Packaging materials

 An establishment that packages cells, tissues or organs must ensure that it uses appropriate packaging materials that are free from damage and capable of maintaining the integrity of the cells, tissues and organs.

Labelling

Marginal note:Language requirement

 All of the information that is required by these Regulations to appear on a label or package insert must be in either English or French.

Marginal note:Cells, except islet cells
  •  (1) An establishment that distributes cells, except islet cells, must ensure that all of the applicable information, as indicated by an “X”, set out in the table to this subsection is provided on the interior label, in the package insert and on the exterior label.

    TABLE TO SUBSECTION 30(1)

    LABELLING REQUIREMENTS FOR CELLS, EXCEPT ISLET CELLS

    Column 1Column 2Column 3Column 4
    From retrieval establishment to transplant establishmentFrom retrieval establishment to cell bankFrom cell bank to any other establishment
    ItemRequired informationInterior labelPackage insertExterior labelInterior labelPackage insertExterior labelInterior labelPackage insertExterior label
    Information about donor and cell
    1.Name of cellXXXXXX
    2.Description of cellXXX
    3.Donor identification code, clearly labelled as suchXXXX
    4.Information capable of identifying the donorXX
    5.Donor assessment recordX
    6.ABO group and Rh factor of donor, if applicableXXXXXX
    7.The hazard symbol entitled “Biohazardous Infectious Material” set out in Schedule II to the Controlled Products Regulations, if applicableXXXXXX
    Retrieval information
    8.Date, time and time zone of retrievalXX
    9.Information specific to retrieval procedureXX
    Processing information
    10.Name of anticoagulant and other additive, if applicableXXX
    11.Statement “For Autologous Use Only”, if applicableXXXXXX
    Information for transplant establishment
    12.Statement that the cell has been declared safe for transplantationX
    13.Statement “For Exceptional Distribution”, if applicableXX
    14.If applicable, the reasons for exceptional distribution and a statement of how the cell does not meet the requirements of these RegulationsXX
    15.Instructions on how to report errors, accidents and adverse reactionsX
    16.Expiry date and time, if applicableXX
    Establishment information
    17.Name of retrieval establishment, its civic address and contact informationXXXX
    18.Name of source establishment, its civic address and contact informationXXXXXX
    19.Registration number of source establishment, clearly labelled as suchXXXX
    20.Name of transplant establishment, if known, its civic address and contact informationXX
    Storage information
    21.Statement “Human cells for transplant”XXX
    22.Handling instructions for storage and for storage during transportationXXX
  • Marginal note:Pancreas and islet cells

    (2) An establishment that distributes a pancreas for islet cell transplantation, or islet cells, must ensure that all of the applicable information, as indicated by an “X”, set out in the table to this subsection is provided on the interior label, in the package insert and on the exterior label.

    TABLE TO SUBSECTION 30(2)

    LABELLING REQUIREMENTS FOR PANCREAS AND ISLET CELLS

    Column 1Column 2Column 3
    PANCREAS: From retrieval establishment to source establishmentISLET CELLS: From source establishment to any other establishment
    ItemRequired informationInterior labelPackage insertExterior labelInterior labelPackage insertExterior label
    Information about donor and organ or islet cells
    1.Name of organ or cells, as applicableXXXX
    2.Description of organ or cells, as applicableXX
    3.Donor identification code, clearly labelled as suchXX
    4.Information capable of identifying the donorXX
    5.Donor assessment recordX
    6.ABO group and Rh factor of donor, if applicableXXXX
    7.The hazard symbol entitled “Biohazardous Infectious Material” set out in Schedule II to the Controlled Products Regulations, if applicableXXXX
    Retrieval information
    8.Date, time and time zone of asystole or aortic clamping, if applicableX
    9.Date, time and time zone of retrievalX
    10.Information specific to retrieval procedureX
    11.Name of perfusion solutionX
    Processing information
    12.Name of storage solutionX
    13.Name of additives, if applicableX
    Information for establishments
    14.Statement that the cells have been declared safe for transplantationX
    15.Statement “For Exceptional Distribution”, if applicableXXX
    16.If applicable, the reasons for exceptional distribution and a statement of how the organ or cells do not meet the requirements of these RegulationsXX
    17.Instructions on how to report errors, accidents and adverse reactionsXX
    18.Expiry date and time, if applicableXX
    Establishment information
    19.Name of retrieval establishment, its civic address and contact informationXXXX
    20.Name of source establishment, its civic address and contact informationXXXX
    21.Registration number of source establishment, clearly labelled as suchXXXX
    22.Name of other establishment, its civic address and contact informationX
    Storage information
    23.Statement “Human organ for transplant” or “Human cells for transplant”, as applicableXX
    24.Handling instructions for storage and for storage during transportationXX